Stryker craniomaxillofacial kalamazoo mi 49002 usa.
Ct scan obital floor plate.
A ct scan was obtained in 13 patients.
A 3 d ct of unilateral clinical anophthalmia with hypoplasia of the ipsilateral bone.
These plates consist of implants that closely approximate the topographical anatomy of the human orbital floor and medial wall and are intended for use in a selective craniomaxillofacial trauma.
This is typically caused by a direct blow to the central orbit from a fist or ball.
The use of a polydioxanone pds plate for orbital reconstruction was evaluated in 20 patients with various traumatic defects of the orbital floor.
This x ray shows the classic transition zone.
Epidemiology the blowout fracture is t.
They will take pictures of the eye and the eye socket including x rays and ct scans.
To check for an orbital fracture an ophthalmologist will examine the eye and the area around it.
An orbital blowout fracture is a traumatic deformity of the orbital floor or medial wall typically resulting from impact of a blunt object larger than the orbital aperture or eye socket most commonly the inferior orbital wall i e.
The matrixmidface preformed orbital plates are designed from ct scan data.
Coronal slice of a postoperative ct scan taken after transconjunctival repair of the complete left medial orbital wall and orbital floor.
The overlying colored line in the medial wall and orbital floor area indicate the preoperative virtual planning that is superimposed on the mesh reconstructed area.
54 04005 3d orbital floor plate right large 54 04006 3d orbital floor plate left small 54 04007 3d orbital floor plate left large storage.
Orbital blowout fractures occur when there is a fracture of one of the walls of orbit but the orbital rim remains intact.
We use ct scan data to design the titantium implants to approximate the anatomy of the orbital floor and medial wall.
The ophthalmologist will check to see if the eye moves as it should and if there are any vision problems.
Plate borders medial wall orbital floor designed from ct scan data the three dimensional implants closely approximate the topographical anatomy of the hu man orbital floor and medial wall to provide accurate recon struction even after significant two wall fractures 5 6 preformed three dimensional shape.
Plate designed from ct scan data to approximate solutions anatomy of orbital floor and medial wall orbital floor.
The follow up time was 9 to 45 months mean 20 4 months.
The floor is likely to collapse because the bones of the roof and lateral walls are robust.